SINAMICS V20 1AC200-240V -15/+10% 47-63HZ RATED POWER 2.2kW WITH 150% OVERLOAD FOR 60SEC INTEGRATED FILTER C1 I/O-INTERFACE: 4DI, 2DO,2AI,1AO FIELDBUS: USS/ MODBUS RTU WITH INBUILT BOP PROTECTION: IP2. Product Code: - 6SL32105BB222BV1. Oct 31, 2018 To setup the inverter in modbus mode i have followed the v20 example modbus document on page 13. (CN011 setting, just puts it into Modbus mode) Notice on the same document the first few pages show the control word STW. This is used to control/ turn the motor on and off. The register for this is shown on the other document (Inverter manual) if.

Hello everyone,

I'm trying to use an arduino Duamelinove to comunicate with a Sinamics V20 inverter via RS485. I have a shield to convert the RS232 from the arduino to the RS485 from the inverter. I also have a RS485/USB adapter to monitor the communication from a computer.

I've loaded the SimpleModbusMaster library example on the arduino, and I'm getting transmission errors on the computer monitor (values different from what was transmited). The inverter receives the signal, but it returns a 'parity error'.

I also tried communicating the inverter with the computer, without the arduino, using a Modbus Master demo and, this time, it returns a 'character structure error'.

Has anyone ever tryied to do something similiar before? I'm not sure if this is even possible as everything I find online mention only communication between Siemens Inverters with Siemens PLCs.

Sinamics v20 modbus register code

Sinamics V20 Modbus Register Code

Modbus

Any thoughts would be appreciated.

Sinamics V20 Modbus Register

Siemens Sinamics V20 Smart Access

Hello everyone,

V20Sinamics v20 parameter setting

I'm trying to use an arduino Duamelinove to comunicate with a Sinamics V20 inverter via RS485. I have a shield to convert the RS232 from the arduino to the RS485 from the inverter. I also have a RS485/USB adapter to monitor the communication from a computer.

Modbus Register Map

I've loaded the SimpleModbusMaster library example on the arduino, and I'm getting transmission errors on the computer monitor (values different from what was transmited). The inverter receives the signal, but it returns a 'parity error'.

Sinamics V20 Modbus Register Product

I also tried communicating the inverter with the computer, without the arduino, using a Modbus Master demo and, this time, it returns a 'character structure error'.

Has anyone ever tryied to do something similiar before? I'm not sure if this is even possible as everything I find online mention only communication between Siemens Inverters with Siemens PLCs.

Sinamics V20 Modbus Register Free

Any thoughts would be appreciated.